Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Medicina (Kaunas) ; 60(3)2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38541197

RESUMO

Background and Objectives: This study examined how a history of thyroid surgery impacts the precision of cricothyroid membrane (CTM) identification through palpation (validated by ultrasound) in female patients visiting the operating room for surgeries unrelated to neck procedures. Materials and Methods: This prospective observational cohort study enrolled adult female patients undergoing elective non-neck surgery, dividing them into control (no thyroid surgery history; n = 40) and experimental (with thyroid surgery history; n = 40) groups. CTM identification was performed by palpation and confirmed via ultrasound. Results: There were no significant differences between two groups in the demographic characteristics of the patients. The success rate and accuracy of CTM identification through palpation were significantly higher in the control group compared to the experimental group (90% vs. 42.5%, respectively; p < 0.001). For female patients with a history of thyroid surgery, the sensitivity of successful CTM palpation was 42.5%, and the specificity was 10%. These figures are based on the calculated true positives (17), false positives (36), true negatives (4), and false negatives (23). Conclusions: Thyroid surgery history in female patients may hinder the accurate palpation-based identification of the CTM, suggesting a need for enhanced clinical practices and considerations during airway management training.


Assuntos
Cartilagem Cricoide , Glândula Tireoide , Adulto , Humanos , Feminino , Estudos Prospectivos , Cartilagem Cricoide/diagnóstico por imagem , Cartilagem Cricoide/cirurgia , Cartilagem Tireóidea/cirurgia , Cartilagem Tireóidea/diagnóstico por imagem , Ultrassonografia , Palpação/métodos
2.
Reg Anesth Pain Med ; 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37657889

RESUMO

BACKGROUND: We compared the spread of an injectate into the thoracic sympathetic chain resulting from a single-injection intertransverse process (ITP) block with that of a single-injection PV block at the T2 level. METHODS: Sixteen soft-embalmed cadavers were used. The right hemithorax was randomly allocated to receive either an ultrasound-guided single-injection ITP block or ultrasound-guided single-injection PV block at the T2 vertebral level, with the opposite block administered to the other side. Approximately 10 mL of latex dye solution was injected into each hemithorax using a random allocation technique. The presence of dye at the nerve root in the sympathetic chain and intercostal nerves at the injection and additional levels was examined by dissection. RESULTS: The injectate spread into the T2 sympathetic ganglion on both ITP (11/16, 68.8%) and PV (16/16, 100%) blocks. The ITP block demonstrated greater uniformity of dye staining in both the dorsal rami and dorsal root ganglion, which contrasts with the less consistent staining outcomes of the PV block in these regions. CONCLUSIONS: At the T2 level, we observed a lower efficacy of the ITP block for analgesic coverage of the sympathetic nerve. This suggested a potential preference by clinicians for the application of the T2 PV block over the ITP block, specifically for the management of sympathetically maintained pain in the upper extremities. In addition, our findings may hint at the potential advantages of the ITP block in specific clinical contexts where targeted nerve involvement, such as the medial branch block or dorsal root ganglion block, is sought.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...